Siemens CSM-4 overview
Siemens CSM-4 500-890402 Controllable Signal Module | MXL System Module The Controllable Signal Module CSM-4 provides two fully supervised, programmable notific...
Product details
Manufactured bySiemens
Product groupSignal Modules
DescriptionSiemens CSM-4 500-890402 Controllable Signal Module | MXL System Module
OverviewThe Controllable Signal Module CSM-4 provides two fully supervised, programmable notification appliance circuits.The CSM-4 supplies two Class B (Style Y) or Class A (Style Z) type output circuits for the supervision and control of listed audible or visual notification appliances such as horns, bells, strobes, etc. Each circuit can provide up to 1.5 amps (24 VDC) of current to power indicating appliances.Any output on a CSM-4 may be configured as either a supervised connection to a local energy type Master City Box or a supervised connection to a Leased Line remote monitoring system. CSM-4 circuits may also be configured for pre-action or deluge releasing service per NFPA 13, extinguishing agent releasing (Halon, FM-200) per NFPA 12A and NFPA 2001.Each circuit or output may be controlled automatically through the MXL program logic or manually using the MXL keypad. Automatic control may also be time based. Each circuit or output can be manually “Armed” or “Disarmed through the MXL keypad. When any circuit or output has been “Disarmed,” the MXL LCD annunciator will indicate the affected circuit or output and the “Partial System Disable” LED will illuminate, until the circuit or output has been returned to the “Armed” condition.The CSM-4 contains an on-board microprocessor which allows notification circuit outputs to function in a degrade mode even if the main MXL processor or the local network communication link has failed. Each circuit’s degrade mode of operation can be separately configured to respond to an alarm in the following manner: OFF, ON, CONTINUOSLY or 1 SECOND ON - 1 SECOND OFF. In a degrade mode a CSM-4 will respond to an alarm from any Intelligent/Analog (ALD) initiating device or Conventional Zone (CZM) connected to the same network node.CSM-4 notification appliance circuit outputs may be configured to provide a coded, march time, or uniform code 3 output.This equipment is approved for operation over the temperature range of 0°C to 49°C.
Key FeaturesOperates Audible or Visual Devices 2 Class A (Style Z) or Class B (StyleY) Circuits 24 VDC 1.5 Amps Per Circuit City Tie or Lease Line Output Releasing Service Fully Programmable Coded Audibles On Board Microprocessor March Time/Uniform Code 3 Selectable Degrade Operation Silencable/Non-Silencable Option Automatic/Manual Control Circuits Power Limited Per NEC 760 Listed, ULC Listed CSFM, NYMEA, FM Approved NFPA 13, Pre-Action and Deluge NFPA 2001, FM-200 Releasing NFPA 12A, Halon Releasing
Manufacturer, product group, and supply
See who makes this product, where it belongs, and where available inventory may be listed.
Available from
1 marketplace offer
Compare sellers and inventory
Where to buy
Total 1 item.