StockCheck - Aggregating Everything
✓Product overview DISC

07-AECRC-CR

DISC · Radchex Meters

DISC 07-AECRC-CR

Images are for reference only. The actual item may differ in appearance, labeling, revision, firmware or condition. Please verify the part number and specifications before ordering.

DISC 07-AECRC-CRDISC 07-AECRC-CR

DISC 07-AECRC-CR overview

07-AECRC-CR is a radchex meter made by DISC. DISC DIAGNOSTIC IMAGING SPECIALISTS CORP. 07-AECRC-CR Wireless CR Radchex Meter is a factory, radiation-calibrated and NIST traceable light meter that can be used to calibrate (balance) CR plate readers (also radiation-calibrated light meters) in the field. X-ray energy…

Manufactured byDISC
Part number or family07-AECRC-CR
Product typeRadchex Meter

Product details

Manufactured byDISC
Product typeRadchex Meter
DescriptionDISC DIAGNOSTIC IMAGING SPECIALISTS CORP. 07-AECRC-CR Wireless CR Radchex Meter is a factory, radiation-calibrated and NIST traceable light meter that can be used to calibrate (balance) CR plate readers (also radiation-calibrated light meters) in the field.
SpecificationsX-ray energy dependence:Digital range:Minimum CRLU Rate:Maximum CRLU Rate:Power On/Off:Controls:Functions:Power requirements:Typical battery life between charging:Operating environment:X-ray beam filter: Electronic Cassette: Dimensions:Weight:Simulates relative light output of Photostimulatable Phosphor Plate (PSP) within +/- 3% over kVp range of 60 to 120 kVp and a patient equivalent thickness range of 5 to 35 cm (within specified operating rates). Computed Radiography Light Units; CRLU (AEC#); 0 to 500.00 1.50/sec (approx 0.15mR/sec(1.315 µGy/sec) entrance exposure rate) 2500/sec (approx 250mR/sec(2193 µGy/sec) entrance exposure rate) Manual switchWireless communications with computer software; Bluetooth wireless communications. Measures CRLU (AEC#); Converts CRLU to CR manufacturers specific CR plate reader light exposure index value (EI); user selectable. Calculates cassette input exposure values for various X-ray beam conditions (exposure in mR(or uGy) plus backscatter) Built-in NiMH rechargeable battery pack (9.6 V)Greater than 15 hrs. 59 degrees to 95 degrees F (15 to 35 degrees C)1.5 mm copper (B152-110); 6 inches by 6 inches complete with velcro straps to attach to X-ray tube collimator housing10 x 12 x 0.5 inches (24 x 30 x 1.3 cm) 3.9 lb (1.8 kg)

Manufacturer, product group, and supply

See who makes this product, where it belongs, and where available inventory may be listed.

Manufactured by DISC View DISC profile
Product type Radchex Meter Explore Radchex Meters
Available from 1 marketplace offer Compare sellers and inventory


Where to buy


Total 1 item.
Green Eagle Logistics 07-AECRC-CR
Verified marketplace seller
0 items available