Product details
Manufactured byFiretrol
Product groupModules
DescriptionFiretrol FTA2000 Series Mark III Medium Voltage Electric Fire Pump Controllers
OverviewFiretrol® FTA2000 combined automatic and manual class E2 medium voltage controllers are intended for starting of squirrel cage motors driving listed fire pumps.
ApprovalsFiretrol fire pump controllers are listed by Underwriters’ Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code.
Key FeaturesCurrent Limiting Fuses designed to hold 600% of motor full load current for minimum 100 sec. Locked Rotor Protection set at 600% of motor full load current designed to trip between 8 and 20 seconds Vacuum Type Motor Contactor Flange Mounted Single Handle Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Daylight Savings Time Option Elapsed Time Meter 7.0” LCD color touch screen (HMI technology) software upgradeable operator interface powered by an embedded microcomputer with software PLC logic. 500 PSI Pressure Transducer (calibrated for 300 PSI (20.7 Bar)) and Test Solenoid for fresh water applications, externally mounted with protective cover Audible Alarm Bell Pump Room Ambient Temperature Switch, Display and Alarms Pressure and Event Recording with Date Stamp to System Memory Accessible VIA The User Interface and Downloadable to a USB Flash Drive Modbus Communications with TCP/IP frame format and a shielded female RJ45 connector NEMA Type 2 (IEC IP22) enclosure with back, top and bottom removable gland plates, lockable handle and controller lifting lugs The controller supplies visual indication of the following: Power Available • Motor Run • Periodic Test • Manual Start • Deluge Valve Start • Remote Automatic Start • Remote Manual Start • Emergency Start • Pump On Demand (Automatic Start) • Low Discharge Pressure • Pump Room Temp. • Lockout The controller displays visual indication for the following alarm conditions: Control Voltage Not Healthy • Fail To Start • Invalid Cut-In • Locked Rotor • Loss of Power • Low Ambient Temp. • Low Water Level • Motor Trouble • Phase Reversal • Under/Over current • Under/Over voltage • Phase Loss L1 / L2 / L3 • Phase Unbalanced • Pressure Transducer Fault Detected • Pump Room Alarm • Service Required • Check Test Solenoid • Weekly Test Cut-In Reached Audible and Visible Indication for Fail To Start. DPDT 8A, 250VAC remote alarm contacts are provided for: Power Available • Phase Reversal • Motor Run • Common Pump Room Alarm (Overvoltage / Undervoltage / Phase Unbalance / Low Pump Room Temp. / High Pump Room Temp) • Common Motor Trouble (Overcurrent / Fail To Start / Undercurrent / Ground Fault) Field Adjustable Timers with Visual Countdown for Minimum Run (Off Delay), Sequential Start (On Delay) and Weekly Test
Manufacturer, product group, and supply
See who makes this product, where it belongs, and where available inventory may be listed.
Manufactured by
Firetrol
View Firetrol profile
Product group
Modules
Explore Modules
Available from
Sourcing support available
Start a sourcing request