Emerson LPS48E1 overview
LPS48E1 by Emerson is listed under RECTIFIERS AND CONVERTERs. LPS48E1 is a –48VDC digital power plant that operates with 200 Amp Power Conversion Units (PCUs). Two input options are currently available: 480VAC and 208/240VAC Emerson Network Power LPS48E1 LPS Series Power Platform | –48VDC Digital Power Plant A…
Specifications
| Two input options are currently available | 480VAC and 208/240VAC |
|---|---|
| Voltage | 480 V AC |
Product details
Manufactured byEmerson
Product typeRECTIFIERS AND CONVERTERs
DescriptionLPS48E1 is a –48VDC digital power plant that operates with 200 Amp Power Conversion Units (PCUs). Two input options are currently available: 480VAC and 208/240VAC
More detailsEmerson Network Power LPS48E1 LPS Series Power Platform | –48VDC Digital Power Plant
Key FeaturesA patented internal bus work that improves AC and DC cable routing options. A modular distribution design that includes built-in monitoring for both fuses and breakers. An integrated DC bus that eliminates costly overhead busses and eases plant expansion. An integrated LMS1 design that simplifies monitoring of external equipment. A controller with a backplane that accepts plug-in MCA alarm cards, MCA I/O cards, and LMS I/O cards.
OverviewLPS48E1 is a –48VDC digital power plant that operates with 200 Amp Power Conversion Units (PCUs). Two input options are currently available: 480VAC and 208/240VAC. Each bay provides power conversion and distribution – up to ten PCUs (2000A total) along with 2400A of distribution. Larger plants up to 10,000A are created by adding secondary bays.The heart of this system is the LPS200E50 (480VAC) or LPS200D50 (208/240VAC) PCU. A true three-phase three-wire rectifier, the unit operates at 0.998 power factor and with less than 5% THD. It can deliver 110% of rated current up to 40°C, and a reduced amount up to 80°C by virtue of its thermal current limit feature. Designed for positive ground applications, the normal output voltage ranges from 47 to 58 volts, with a test voltage adjustable down to 45 volts.AC service is wired individually to each PCU. A horizontal terminal strip is located on the left top of the bay. An optional Power Distribution Service Cabinet (PDSC) bolted to the left side of the bay facilitates wiring in one or two AC branch circuit applications. Distribution is divided into two rows, top and bottom. Each row has a flexible design that accommodates breakers and fuses, up to a 1200 amps maximum. There can be up to 24 (3-100A) breakers/fuses or up to 12 (100-800A) devices, or a combination. Elements of 100A and greater include a shunt for monitoring by the meter, control and alarm (MCA) panel.The MCA provides a multi-line vacuum fluorescent display. It also consists of a removable CPU, alarm cards, and optional input/output (I/O) cards. These are located in a shelf below the distribution. The shelf is dual-purpose and also accepts an LMS CPU for modem and Ethernet access, plus LMS I/O cards for other monitoring points.As a system, the MCA controls the steady state output voltage to within 0.05% of any setting, from no load to full load. The MCA also uses a patented algorithm to balance the PCU output currents to within 1% of their rated current.
Manufacturer, product group, and supply
See who makes this product, where it belongs, and where available inventory may be listed.
Manufactured by
Emerson
View Emerson profile
Product type
RECTIFIERS AND CONVERTERs
Explore RECTIFIERS AND CONVERTERs Explore DC Digital Power Plants Explore Power Platforms