Alnor Instrument Co. 656-004-003 overview
656-004-003 is a dew point meter made by Alnor Instrument Co.. Alnor Instrument 656-004-003 7000U Series Dew Point Meter, -23°C 120V Scale Temperature Limit VoltageDew points of gases are determined quickly and accurately with the Dewpointer. The Dewpointer is completely portable, easy to operate and extremely…
Manufactured byAlnor Instrument Co.
Part number or family656-004-003
Product typeDew Point Meter
Specifications
| Voltage | 120 V |
|---|
Product details
Manufactured byAlnor Instrument Co.
Product typeDew Point Meter
DescriptionAlnor Instrument 656-004-003 7000U Series Dew Point Meter, -23°C 120V Scale Temperature Limit VoltageDew points of gases are determined quickly and accurately with the Dewpointer. The Dewpointer is completely portable, easy to operate and extremely reliable. Readings are reproducible and easily translated to relative humidity, parts per million, pounds per 1000 cubic feet, or other appropriate engineering measurements.Dewpointers can also be provided with Americium to increase accuracy, allow for readability to -80°F, and minimize variability of gas samples.Dewpointer applications include air dryers, heat treating furnaces, welding operations, natural gas transmission and any other application where the dryness of air or gas is critical.General Industrial Model 7000UModel 7000-U is a general purpose Dewpointer suitable for measurements from 10° below ambient to -10°F (ambient less 10°C to -23°C). Measurements from 10°F below ambient to -80°F (ambient less 10°C to -62°C) can be obtained with the Americium 241 option.General Industrial Model 7200U Model 7200U is similar to Model 7000U, but is for use with gas already under pressure.Americium Foil -OptionalThe formation of a visible fog at the dew point temperature depends on the presence of particles in the gas to act as nuclei around which the droplets can form. In practically all cases, those particles are always present. If, however, the gas is completely dust free it would be possible to cool the gas below the dew point temperature without condensing the moisture. This is referred to as “supercooling” and it is a serious source of error in the attempts to measure low dew point temperatures. It is in the effort to eliminate this kind of error that DICKEY-john uses Americium 241 to ionize the gas in the fog chamber and provide particles upon which water vapor can condense and develop a fog.
Manufacturer, product group, and supply
See who makes this product, where it belongs, and where available inventory may be listed.
Manufactured by
Alnor Instrument Co.
Product type
Dew Point Meter
Explore Dew Point Meters
Available from
Sourcing support available